Interpretation I-26-02: Historic Building Type B Unit Exemption


Read time: 6 minutes

This interpretation is being issued in response to a request with the following question related to Section 306.7.16.7 of the 2021 International Existing Building Code (IEBC), as adopted in the 2022 Connecticut State Building Code (CSBC), for Type B accessible dwelling units in a historic building undergoing a change of occupancy where interior partitions are added to create new dwelling units.

 

Question #1: 

I am currently reviewing  a change of occupancy of a 5-story building that has offices and other commercial occupancies and is being converted to R-2 apartments. Obviously, the building is undergoing a complete change of occupancy, and the alterations involve 100% of the building. The building is listed as historic.

The architect is trying to use IEBC section 306.7.16.7 and claims that he does not have to create Type B dwelling units. That section has to do with alterations which presumes there are already dwelling units in the building, and he would not have made existing dwelling units meet the criteria of Type B. If they are already adding loads of partitions in this building to create dwelling units, it would seem to me that 306.5 would apply, especially seeing that alterations encompass more than 50% of the building. The primary function of an apartment building is dwelling units, so I am thinking that 306.7.1 would require them to provide an accessible route to the apartments as well.

It was brought to my attention that code interpretation I-24-01 is leading architects to believe that NO Type B dwelling units are required at all under any circumstances when an historic building is undergoing a complete change of occupancy. In the case of the project, I am reviewing the change is from B to R-2, 5 stories, with elevators, creating 65 dwellings units where there were none, and the architect contends that no Type B dwelling units are required.

Are they exempt from creating Type B dwelling units?

 

Answer #1:

Section 306.5 requires a change of occupancy to comply with Section 306.7. However, under the exception to Section 306.5 and the provisions of Section 306.7.4, Type B units are not required when alterations affect 50% or less of the building’s total area. When alterations affect more than 50% of the total building area, the project must comply with the alteration requirements of Section 306.7.

Section 306.7.16 provides limited relief from requirements for accessible routes, entrances, and toilet rooms in historic structures. This relief applies only when compliance would threaten or destroy the structure’s historic significance and therefore would be technically infeasible. When that condition is met, the alternative requirements of Sections 306.7.16.1 through 306.7.16.5 may be used. In addition, Section 306.7.16.7 provides that Type B dwelling or sleeping units are not required.

Interpretation I-24-01 confirms that a historic building may be exempt from providing Type B units when compliance would affect interior elements that contribute to the building’s historic designation. It is not intended to create a blanket exemption for all historic buildings; Section 306.7.16 applies only when compliance would “threaten or destroy the historic significance” of the building. If the interior is being newly constructed and no existing historic elements require protection, the exception under Section 306.7.16.7 does not apply.

 

Sincerely,

 

Omarys Vasquez, AIA NOMA

State Building Inspector